在Cisco Server的DRAC中, 创建virtual drive时, 会看到下面的选项.
那么Write back, write through, write back bad BBU之间的区别是什么呢?
Cisco官网解释如下:
=================
Write through
Write back
Write back bad BBU
Write back good BBU
简单点说, write back bad BBU性能好, 但不安全, 因为BBU坏了, 一旦断点, 就会有cache里的没被写到盘上的数据丢失.
write through安全, 但写性能不好, 因为要cache和盘上都要写, 写到盘上好了才算是写好了, 读性能提高因为刚写的数据在cache里可以读到, 然并卵.
write back性能好, 也安全, 因为bbu坏了, 他就自动变为write through.
注意, 对于SSD(固态硬盘)来说, write back是不合适的, 因为SSD的写本来就不慢, 用write back的话, 就是说cache要写一次, 后面SSD上还要写一次.
做个顾名思义的版本吧:
Write back (to disk from cache when needed)
Write through (cache directly to disk and make a copy to cache)
Write back (to disk from cache even when) bad BBU (happens)
Write back (to disk from cache only when)good BBU (is there)
参考资料
========================
Cisco UCS C-Series Servers Integrated Management Controller GUI Configuration Guide, Release 1.5
LSI
http://wiki.mikejung.biz/LSI#LSI_Write_Caching_Configuration
注: 之前不仔细, 弄串了write through和write back的顺序, 不过好在列出了原文, 看了觉得混乱的应该会看看原文的吧. 希望大家原谅.