Question:

做FOLDER文件夹功能,打开FORM错误提示:

FRM-99999:出现1412错误。有关该错误的详细信息,请参阅发行说明文件(relnotes)

Answer:

原因是FOLDER主块上没有设滚动条。

Oracle Form Developer:  Folder FRM-99999 Error 14212-LMLPHP

 

Tips:

Undocumented Error Messages (FRM-99999)

Any Forms error message not documented in the online help will display a generic
message:

FRM-99999 Error FRM-nnnnn occurred, please consult the release notes.

The details of these error messages are documented in the following subsections:

o    Error Messages 1412 and 1413

o    Error Message 93000

o    Error Messages 10905-10909

o    Error Messages 13009-13010

o    Error Messages 18114-18121

Error Messages 1412 and 1413

FRM-99999,
Error 1412.
    An attempt was made to set scrollbar position on a block that
has no scrollbar.

FRM-99999,
Error 1413.
    An attempt was made to get scrollbar position on a block that
has no scrollbar.

05-11 10:54