网上找的代码,还没经过验证
/// <summary>
/// Bulk inserts multiple rows to SQL
/// </summary>
/// <param name="tableName">The name of the table to insert into</param>
/// <param name="primaryKeyName">The name of the primary key column of the table</param>
/// <param name="autoIncrement">True if the primary key is automatically allocated by the DB</param>
/// <param name="pocos">The POCO objects that specifies the column values to be inserted</param>
/// <param name="batchSize">The number of POCOS to be grouped together for each database rounddtrip</param>
public void BulkInsert(string tableName, string primaryKeyName, bool autoIncrement, IEnumerable<object> pocos, int batchSize = )
{
try
{
OpenSharedConnection();
try
{
using (var cmd = CreateCommand(_sharedConnection, ""))
{
var pd = PocoData.ForObject(pocos.First(), primaryKeyName);
// Create list of columnnames only once
var names = new List<string>();
foreach (var i in pd.Columns)
{
// Don't insert result columns
if (i.Value.ResultColumn)
continue; // Don't insert the primary key (except under oracle where we need bring in the next sequence value)
if (autoIncrement && primaryKeyName != null && string.Compare(i.Key, primaryKeyName, true) == )
{
// Setup auto increment expression
string autoIncExpression = _dbType.GetAutoIncrementExpression(pd.TableInfo);
if (autoIncExpression != null)
{
names.Add(i.Key);
}
continue;
}
names.Add(_dbType.EscapeSqlIdentifier(i.Key));
}
var namesArray = names.ToArray(); var values = new List<string>();
int count = ;
do
{
cmd.CommandText = "";
cmd.Parameters.Clear();
var index = ;
foreach (var poco in pocos.Skip(count).Take(batchSize))
{
values.Clear();
foreach (var i in pd.Columns)
{
// Don't insert result columns
if (i.Value.ResultColumn) continue; // Don't insert the primary key (except under oracle where we need bring in the next sequence value)
if (autoIncrement && primaryKeyName != null && string.Compare(i.Key, primaryKeyName, true) == )
{
// Setup auto increment expression
string autoIncExpression = _dbType.GetAutoIncrementExpression(pd.TableInfo);
if (autoIncExpression != null)
{
values.Add(autoIncExpression);
}
continue;
} values.Add(string.Format("{0}{1}", _paramPrefix, index++));
AddParam(cmd, i.Value.GetValue(poco), i.Value.PropertyInfo);
} string outputClause = String.Empty;
if (autoIncrement)
{
outputClause = _dbType.GetInsertOutputClause(primaryKeyName);
} cmd.CommandText += string.Format("INSERT INTO {0} ({1}){2} VALUES ({3})", _dbType.EscapeTableName(tableName),
string.Join(",", namesArray), outputClause, string.Join(",", values.ToArray()));
}
// Are we done?
if (cmd.CommandText == "") break;
count += batchSize;
DoPreExecute(cmd);
cmd.ExecuteNonQuery();
OnExecutedCommand(cmd);
}
while (true); }
}
finally
{
CloseSharedConnection();
}
}
catch (Exception x)
{
if (OnException(x))
throw;
}
} /// <summary>
/// Performs a SQL Bulk Insert
/// </summary>
/// <param name="pocos">The POCO objects that specifies the column values to be inserted</param>
/// <param name="batchSize">The number of POCOS to be grouped together for each database rounddtrip</param>
public void BulkInsert(IEnumerable<object> pocos, int batchSize = )
{
if (!pocos.Any()) return;
var pd = PocoData.ForType(pocos.First().GetType());
BulkInsert(pd.TableInfo.TableName, pd.TableInfo.PrimaryKey, pd.TableInfo.AutoIncrement, pocos);
}
摘自:http://stackoverflow.com/questions/6595105/bulk-insert-update-with-petapoco/14479073