问题描述
升级到 Protractor 4.0.0 并因重大更改调整配置后,我们终于启动了测试.
After upgrading to Protractor 4.0.0 and adjusting the config because of the breaking changes, we finally have our tests launching.
现在,问题是在测试运行后它失败了:
Now, the problem is that after a test run it fails with:
[09:52:22] E/launcher - "process.on('uncaughtException'" error, see launcher
[09:52:22] E/launcher - Process exited with error code 199
如何调试此问题并了解导致该问题的原因?
How to debug this problem and understand what is causing it?
尝试在疑难解答"模式下运行量角器:
Tried to run Protractor in "troubleshoot" mode:
$ protractor config/local.conf.js --troubleshoot
但得到了完全相同的输出,没有关于错误的详细信息.
but got exactly the same output with no details about the error.
推荐答案
这是目前正在修复应该很快就会修复.快速修复(在发布热修复之前)是更改 node_modules 中的代码或恢复到 3.3.0.
This is currently being fixed and there should be a hot fix out soon. The quick fix (before the hot fix is released) is to change the code in your node_modules or revert to 3.3.0.
Edit node_modules/protractor/built/launcher.js
将第 168 行的 uncaughtException
替换为:
Edit node_modules/protractor/built/launcher.js
replace the uncaughtException
at line 168 with:
process.on('uncaughtException', function (e) {
var errorCode = exitCodes_1.ErrorHandler.parseError(e);
if (errorCode) {
var protractorError = e;
exitCodes_1.ProtractorError.log(logger, errorCode, protractorError.message, protractorError.stack);
process.exit(errorCode);
}
else {
logger.error(e.message);
logger.error(e.stack);
process.exit(exitCodes_1.ProtractorError.CODE);
}
});
这篇关于量角器运行后未捕获异常的文章就介绍到这了,希望我们推荐的答案对大家有所帮助,也希望大家多多支持!