本文介绍了如果下游作业失败,将上游Jenkins / Hudson标记为失败的处理方法,对大家解决问题具有一定的参考价值,需要的朋友们下面随着小编来一起学习吧!
问题描述
我使用
I am using Parameterized Trigger Plugin to trigger a downstream build.
How do I specify that my upstream job should fail if the downstream fails? The upstream job is actually is dummy job with parameters being passed to the downstream.
解决方案
Make sure you are using the correct step to execute your downstream jobs; I discovered that since I was executing mine as a "post build step", I didn't have the "Block until the triggered projects finish their builds" option. Changing that to "build task" as opposed to a "post build task", allowed me to find the options you are looking for within the Parameterized Trigger Plugin.
这篇关于如果下游作业失败,将上游Jenkins / Hudson标记为失败的文章就介绍到这了,希望我们推荐的答案对大家有所帮助,也希望大家多多支持!