问题描述
使用 VS 2008,这是我的 COM 对象
Using VS 2008, here is my COM object
using System;
using System.Collections.Generic;
using System.Text;
using System.Runtime.InteropServices;
using System.Windows.Forms;
namespace TestCom
{
[Guid("9E5E5FB2-219D-4ee7-AB27-E4DBED8E123E")]
[ClassInterface(ClassInterfaceType.AutoDual)]
[ProgId("Test9.COMINT")]
public class TestComClass
{
public void Init(string userid, string password)
{
MessageBox.Show(string.Format("{0}/{1}", userid, password));
}
}
}
如果我按如下方式构建并在生产机器上注册它
If I build this and register it on a production machine as follows
REGASM /CODEBASE TESTCOM.DLL
从一个简单的 VB6 应用程序可以正常工作
From a simple VB6 app this works fine
Private Sub Form_Load()
Dim o As Object
Set o = CreateObject("Test9.COMINT")
o.Init "A", "B"
End Sub
在 Excel 中从 VBA 调用的完全相同的代码给出了
This exact same code called from VBA in Excel gives
自动化错误"(0x80131700)
在开发机器上一切正常,只是在只安装了 .NET 和 MS Office 的生产机器上不行.
Everything works fine on a development machine, just not on a production machine with just .NET and MS Office installed.
我认为这与在 Excel 下运行时未正确初始化的 .NET 框架有关.如果我使用 Filemon,我可以看到它四处寻找 MSCORWKS.DLL.当我从 VBScript 调用同一个对象时,它发现 MSCorwks.dll 很好.
I think this is something to do with the .NET framework not being initialized properly, when running under Excel. If I use Filemon I can see it skip around looking for MSCORWKS.DLL. When I call the same object from VBScript, it finds MSCorwks.dll fine.
当我从 VBA 调用 CorBindToCurrentRunTime
以尝试强制加载 CLR 时,有趣的是,我得到的 HRESULT (0x80131700)
与执行 CreateObject()
在 VBA 中.
When I called CorBindToCurrentRunTime
from VBA to try to forcibly load the CLR, interestingly I get the exact same HRESULT (0x80131700)
as when I do CreateObject()
in VBA.
因此我认为这是一个框架初始化问题.
Therefore I think it is a framework initialization issue.
推荐答案
我将回答我自己的问题,希望能帮其他人省去我刚刚忍受的乏味苦差事.
I'm going to answer my own question, hopefully to spare others the hours of tedious drudgery I have just endured.
如果你得到这个,它是因为基于 .NET 的 COM 程序集找不到 .NET 框架
If you get this, it is because the .NET based COM assembly can't find the .NET framework
解决方案很简单.创建一个包含以下内容的文件
The solution is simple. Create a file containing the following
<?xml version="1.0"?>
<configuration>
<startup>
<supportedRuntime version="v2.0.50727"/>
</startup>
</configuration>
将其命名为Excel.Exe.Config"并将其放在与EXCEL.EXE"相同的目录中
Call it "Excel.Exe.Config" and place it in the same directory as "EXCEL.EXE"
问题解决了!
这篇关于无法从 VBA 实例化用 C# 编写的 COM 对象(VB6 ok)的文章就介绍到这了,希望我们推荐的答案对大家有所帮助,也希望大家多多支持!