使用Roslyn编译为动态程序集时,性能出现问题。编译耗时约3秒钟,而使用CodeDom
编译器则耗时300毫秒来编译相同的代码。这是我用来进行编译的代码的精简版本:
var compilation = CSharpCompilation.Create(
"UserPayRules.dll",
syntaxTrees,
assembliesToAdd);
using (var stream = new MemoryStream())
{
stopWatch.Start();
var result = compilation.Emit(stream);
stopWatch.Stop();
Debug.WriteLine("Compilation: {0}", stopWatch.ElapsedMilliseconds);
if (!result.Success)
{
throw new InvalidOperationException();
}
var assembly = Assembly.Load(stream.GetBuffer());
}
This answer建议将ModuleBuilder对象而不是MemoryStream传递给Emit方法,以加快处理速度。我尝试遵循这种模式,如下所示:
var compilation = CSharpCompilation.Create(
"UserPayRules.dll",
syntaxTrees,
assembliesToAdd);
var assemblyBuilder = AppDomain.CurrentDomain.DefineDynamicAssembly(
new AssemblyName("ThisAssembly"),
AssemblyBuilderAccess.RunAndCollect);
var moduleBuilder = assemblyBuilder.DefineDynamicModule("ThisModule");
var result = compilation.Emit(moduleBuilder);
Debug.WriteLine("Compilation: {0}", stopWatch.ElapsedMilliseconds);
if (!result.Success)
{
throw new InvalidOperationException();
}
var assembly = Assembly.Load(stream.GetBuffer());
但是我的Roslyn版本显然没有采用
Emit
的ModuleBuilder
方法的重载。该版本是:ID: Microsoft.CodeAnalysis
版本: 0.6.4033103-beta(预发行版)
项目信息: http://msdn.microsoft.com/en-US/roslyn
显然,这是一个预发行版本,因此api可能已更改并不奇怪。然而,
我的问题
Emit
方法似乎不再具有需要ModuleBuilder
的重载吗? CodeDom
和Mono编译器相比,我有很多优势,我不想放弃)。 最佳答案
Roslyn当前不具备发出动态程序集的功能。我们删除了它,因为它有问题。
您仍然可以使用MemoryStream
API发出Compilation.Emit
,然后使用Assembly.Load(byte[])
加载生成的二进制文件。
请注意,在卸载包含的AppDomain
之前,不会释放此程序集。
关于c# - 将Roslyn Emit方法与ModuleBuilder而不是MemoryStream一起使用,我们在Stack Overflow上找到一个类似的问题:https://stackoverflow.com/questions/22974473/